起订:1 | 供货总量:114 |
发货期限:自买家付款之日起 1 天内发货 | 所在地:全国 |
有效期至:长期有效 | 品牌: |
详情介绍
咨询:2818592922772057695
深圳市科瑞杰科技有限公司
横河CW500电能质量分析仪
深圳市科瑞杰科技有限公司-YOKOGAWA日本横河CW500电能质量分析仪是一款使用安全电流钳的现场功率测量仪器,具有较高的可操作性,其功能已经超越了目前的CW240钳式功率计。
主要特性与技术指标
通过YOKOGAWA功率计可实现节能:
功率的测量与记录:
一台仪器即可实现电能分析和电能质量控制同时测量3路电压输入
2路直流电压输入
4路电流探头输入
瞬时/评价/值/小值列表或电压/电流/功率/功率因素/相位角/相位超前电容计算
支持用户快速向导功能:
测量前的检测正确接线与设置
自动识别电流探头类型
可分别显示电压,电流的矢量相位差
测量功能:
临时电力故障的测量
连续电流故障测量
谐波闪烁测试
三相电路电压、电流不平衡率测量
CW500Viewer可以PC通讯,可保存积分功率,电能质量数据,主要单元设置数据等
可与外置SD内存卡,USB通讯,蓝牙通讯
趋势图屏幕
The Yokogawa CW500 is a portable power meter that utilizes current clamp-on probes, navigation screens and quick start guides to enable user friendly power consumption and power quality measurements in the field that conform to IEC6100-4-30 Class S.
FEATURES
Power Measurement and Logging
Power Quality Measurement
User Support
Analysis of Data and Report Generation
Power Measuring and Logging
Simultaneously measures 3 CH Voltage input, 4 CH currentclamp probe input, 2 CH DCV input.
Instantaneous/Average/Maximum/Minimum value list or trend graph screen of Voltage/ Current/Power/Power factor/Phase Angle/Phase Advanced Capacitance Calculation.
Integration Value of Active/ Reactive/Apparent Energy are each displayed for consumption and generation.
Demand monitoring which displays screens of present power consumption compared to aimed demand power values.
User Support
Quick Start Guide Function:
The Quick Start Guide Function supports correct wiring and setting before measuring.
The Quick Start Guide Function automatically recognizes the type of current clamp probe.
Vector Display:
The Vector Display indicates Voltage and Current phase difference and values between input channels of voltage and current.
The Vector Display checks whether the wiring is correct or not.
Power Quality Measuring
Measure Temporary Malfunctions of the Power Line
The CW500 captures temporary malfunction phenomena of the power line that can cause malfunction or destruction of devices due to voltage swell, voltage dip, interruption, transientvoltage over, and inrush current by using a high sampling rate of 24 µs and RUS calculation.
Event data contains the type of malfunction, occurred time or occurrence finish time, measured value and waveform of voltage and current of all channels for approx. 200 ms period.
This measurement method conforms to IEC standard 61000- 4-30 Class S
Measure Continuous Malfunction of the Power Line
Harmonics
Measure and display graphs and lists of up to the 50th Harmonic components of voltage, current, and power for each phase and total.
Flicker
Measures 1-minute flicker (Pst, 1 min), short flicker, (Pst) and long flicker (Plt).
Unbalance rate
Displays voltage and current unbalance rate on 3 phase wiring.
CW500Viewer (Included PC software)
Automatically display the graphical and report data by clicking on the file on the PC display.
Manage multiple settings of the unit.
Measure in real-time using USB communication.
Types of data
Integrated power data, power quality event data, main unit setting data, and screen capture data.
Memory card and interface
SD memory card, USB communication, Bluetooth communication (available for US, Canada and Japan only).
FUNCTIONS
Power Measuring
Power line and Input Channel: 3 CH Voltage, 4 CH for Current Clamp Probe.
1P2W (up to 4 systems), 1P3W (up to 2 systems), 3P3W 2current (up to 2 systems), 3P3W 3current, 3P4W
Power measuring item:
Instantaneous, average, maximum, and minimum values for each setting period:
Voltage/Current/Power (Active, Reactive, Apparent)/Power Factor/ Phase Angle/Frequency/Calculated Phase Shift Capacitance/DC voltage value 2 CH.
Integration Value
Energy (active, reactive, apparent), Demand (list or graph display of change in a specific period and as a whole)
Recording Interval Period
1/2/5/10/15/20/30 second, 1/2/5/10/15/20/30 minute, 1 hour/2 hours
Recording method
Manual, time, period
Estimated Recording Length with 2 GB SD card
The recording length shortens according to the number of power quality events.
only the included SD memory card or dedicated SD memory card is guaranteed.
Various Measuring Screens
List display, zoom display by 4 or 8 divisions, trend graph display, integration value display for energy, demand list display of value, demand graph display for change of period, demand graph display for whole recording
List Display
Items of measured values can be selected with the curser key.
Zoom Display
Zoom display can be selected by 4 or 8 divisions.
Trend Graph
Trend graph of voltage/ current/power/power factor/frequency/ advanced phase condenser external DC voltage.
Energy Display
List of active, apparent, reactive by consumption or generation.
Demand measuring
Demand is the average power value of a specific period (usually 30 minutes). The contract with the power supplier conditionally concerns the maximum average power value between a period for the consumption fee. This function supports how to maintain within the target consumption by monitoring the estimated demand value to the setting rate with the maximum demand value.
List of Demand Value
Graph display of change on specific period
Graph display of whole demand trend
Analysis and Reporting of recorded data
Analysis and reporting is enabled by simply clicking on the desired data on the software screen.
Analysis can be viewed by trend graph, overage, maximum and minimum value of voltage current, power, and power factor. Report generating can be set daily by daytime, nighttime, working day, or off day. It can also be set on a monthly period based on daytime or nighttime, working day or off day. Additionally, energy data to quantify into crude oil barrels or CO2 can also be converted.
Trend analysis graph
Sample of report
Power Quality Function
Short period power line malfunctions such as voltage swells, dips, interruptions, transients, over or inrush currents, or long periods of harmonic distortion/flicker may damage or reset your devices.
The CW500 helps to identify each of those short period malfunctions by recording occurrence time, occurrence finish time and waveforms. Additionally there is a digital output on occurrence.
Long period malfunctions can be analyzed by harmonics, flicker, waveform, or by checking on the unbalance rate calculation for a 3 phase measurement.
All data can be finalized into a report format with the included software. The CW500 conforms to the IEC standard of 61000-4-30 Class S.
User Support Function
User Friendly
Quick start guide and automatic type of clamp recognition
The quick start guide will show on-start measuring and how to wire and set the range before measuring. The automatic clamp detection will insure the settings are correct.
Start of guidance
PUSH the “START/STOP” key.
Select “Quick start guide”.
Select recording item.
Wiring
Select the wiring and the appropriate connection diagram will be displayed.
Connect accordingly.
Wiring check/self diag./self id.
Wiring check, self-check and the type of clamp is automatically detected and the results displayed.
If NG is displayed, the detail can be confirmed by pressing the “ENTER” key.
Recording setting
Set the recording interval time and the recording time or period.
Power supply from measuring line
Power (under 240 VAC) can be supplied by using the power supply adapter (sold separately).
Note: This is not available for EV region.
Leakage current measuring
The external magnetic field effect is 0.002 A or less, at 400 A/.
Yokogawa’s proprietary technology has achieved a magnetic field impact amount of 30 ppm even in adjacent power lines (at 100 A).
Below is an example of how to measure a neutral line of 3 phase 4 line.
Multiple line measuring
4 system load measuring
Maximum of 4 systems are capable for 1 phase 2 line wiring.
Maximum of 2 systems are capable for 1 phase 3 line or 3 phase 3 line wiring.
SOFTWARE
Software for Analysis and Setting (Free) CW500Viewer
Data analysis, data reporting, making a setting file and doing a real time measurement can be easily done with the CW500Viewer.
The data can be transferred by SD memory card, USB communication or Bluetooth communication (for USA, Canada, Japan only).
The graph and lists are created by clicking on the data file.
The graph and lists of the recorded data file are created by clicking on the desired data file. They can be displayed and copied on a clipboard so it can be used on other software such as Word or Excel.
The time axis and measure axis can be zoomed in or out easily. With this capability, micro and macro changes can be displayed.
Waveforms of power quality events (Voltage swell, voltage dips, voltage interrupt, voltage transient, (over and inrush current) which are recorded by 200 ms period can be displayed and printed.
The integrated data can be added on one graph, enabling the whole energy integration data to be displayed.
Integrated energy data can be scaled into CO2 or the crude oil value.
Settings management
Setting data can be read out from and to the mainunit via SD memory card, USB communication cable or Bluetooth communication (*1).
Setting data can be easily edited, saved and managed.
Real time measurement
Real time measurement can be performed on up to 2 units simultaneously via USB communication or Bluetooth communication (*1)
System Requirements
横河YOKOGAWA全球权威产品*授权代理:
深圳市科瑞杰科技有限公司
产品信息:
横河YOKOGAWA
功率计:WT210/WT230/WT310/WT322/WT333/WT500/WT1800/WT3000-除WT500外均已停产;
升级版:WT310E/WT330E/WT310E/WT332E/WT333E/WT500/WT1800E/WT3000E.
示波器:DLM2022/ DLM2024/DLM2032/ DLM2034/ DLM2052/ DLM2054/DLM4038/ DLM4058.
数据采集器:MX100/MW100;
版:GM10.
便携式无纸记录仪:MV1004/MV1006/MV1008/MV1012/MV1024/MV2008 MV2010/ MV2020/ MV2030/ MV2040/ MV2048-以上型号均已停产;
升级版:GP10/GP20.
示波记录仪:DL850/DL850V车辆版-均已停产;
升级版:DL850E/DL850EV.
致茂chroma
可编程直流电子负载:6310A/63200/6330A/63600
LED电源测试*直流电子负载:63110A/63113A
可编程交流电子负载:63800
可编程交流电源供应器:61500/600
可编程直流电源供应器:62000P/62000H/62150H-600S/62000B/62000K
电气安规分析仪:19032/19032-P
公司网址:
WWW.KERUIJIE.CN
WWW.KERUIJIE.COM.CN
深圳公司:深圳市龙华新区建设路与东环一路交叉路口恒和大厦1204室
:邓女士
:
华东办事处:江苏省丹阳市中山路106号
:罗先生
:
网友评价 共0条 [查看全部]