起订:1
供应:509
发货:1天内
发送询价
产品特点:• 交直流耐压、绝缘、接地、接触电流、电气性能以及低压启动一键完成• 完全符合IEC、UL、GB等安规要求• 负载容量达8KVA/30Arms,满足大容量负载测试• 可选购RS-232接口• 可搭配华仪电源或1931系列产品使用• 台湾研发制造,品质有保证产品技术参数:INPUTVoltage115 / 230Vac ± 15%Frequency50 / 60Hz ± 5%FusesFuse 6.3A / 250V Slow-Blow RangeResolutionAccuracyAC WITHSTAND VOLTAGEOutput Voltage, KVAC0-3.500.01± (2% of setting + 5V)Output Frequency50Hz/60Hz ±0.1%, User SelectionOutput WaveformSine Wave , Crest Factor = 1.3 - 1.5Output Regulation± (1% of output + 5V), From no load to full loadSETTINGSHI and LO-Limit current, mA0.00-40.000.01± (2% of setting + 2 counts)Ramp Timer, second0.1 - 999.90.1± (0.1% of setting + 0.05 sec)Dwell Timer, second0, 0.2 - 999.9(0=continuous)Current Offset, mA0.00-2.000.01± (2% of setting + 2 counts)DUT OutputON/OFF BY User SelectionArc Detection(Option)1-9 ranges (9 is the most sensitivity)DC WITHSTAND VOLTAGEOutput Voltage, KVDC0 -3.500.01± (2% of setting + 5V)DC Output Ripple<5 % at 4KV/5mASETTINGSHI and LO-Limit current, mA0.00 - 5.000.01± (2% of setting + 2 counts)Ramp Timer, second0.1- 999.90.1± (0.1% of setting + 0.05 sec)Dwell Timer, second0, 0.2 - 999.9(0=continuous)Current Offset, mA0.00 - 0.200.01± (2% of setting + 2 counts)DUT OutputON/OFF BY User SelectionArc Detection(Option)1-9 ranges (9 is the most sensitivity)Discharge TimeNo capacitive Load is < 30 msec, capacitive Load is < 100 msec.Maximum Capacitive Load DC Mode1µF < 1KV,0.5µF < 3KV,0.75µF < 2KV, 0.08µF < 4KVINSULATION RESISTANCEOutput Voltage, DCV100 - 10001± (2% of reading + 5 volts)SETTINGSHI-Limit, resistance, MΩ0,1 - 1000 (0 = OFF)1Same as ResistanceMEASUREMENT AccuracyLo-Limit, resistance,MΩ1 - 1000Delay Timer, second0, 0.5 - 999.9(0=continuous)0.1± (0.1% of setting + 0.05 sec)GROUND BOND Output AC Current, A3.0 – 30.00.1± (2 % of setting + 0.02A)Output Voltage, VacAC 6 volts Max.Output Frequency, Hz50Hz/60Hz ±0.1%, User Selection Milliohm Offset0-1001± (2 % of setting + 2 counts)SETTINGSHI and LO-LimitResistance, mΩ 0 – 510 (3.0-10.0A)0 – 200 (10.1-25.0A)0 – 150 (25.1-30.0A)1± (2 % of setting + 2 counts )Dwell Timer, second0, 0.5 - 999.9 (0 = continuous)0.1± (0.1% of setting + 0.05 sec)MEASUREMENT RangeResolutionAccuracyVoltage, KV(AC/DC)0.00 - 3.500.01± (1.5 % of reading +1 count)Voltage, Vdc (IR only)0 - 10001± (1.5% of reading + 2 counts)AC Current, mA0.00 - 40.000.01± (2% of reading + 2 counts)DC Current, mA0.00 – 5.000.01AC Current, A (G.B)0.0-30.00.1± (3 % of reading + 3 counts)Resistance, MΩ (IR)1-999.90.1/0.01100-499V ± (7% of reading + 2 counts)500-1000V ± (3% of reading + 2 counts)Resistance, mΩ (GB)0-5101± (2 % of reading + 2 counts)RUN TEST DUT POWERAC Voltage0 - 277.0V, Single phase unblance, 0 - 30.0A maximumCurrent30A maximun continuousPower Rating8400W maximumDUT ProtectionShort Circuit current 50A < 3 sec, Inrush Current 180A Response time 10u sec.SETTINGSHI and LO Limit AC Voltage, V0.0-277.00.1± (1.5% of setting + 0.2 V), 60.0-277VHI and LO Limit AC Current, A0.0-30.00.1± (2% of setting + 2 counts)HI and LO Limit AC Power, W0 - 84001± (5% of setting + 6 counts)HI and LO Limit Power Factor0.000-1.0000.001W/VA, calculated and displayed to three significant digitsHI and LO Limit Leakage Current0.0-010.00, Hi-Limit 0=OFF0.01± (2% of setting + 2 counts)Delay Time, second0.2-999.90.1± (0.1% of setting + 0.05 sec)Dwell Time, second0, 0.1-999.9 (0=continuous)MEASUREMENT Range Resolution Accuracy Voltage, Vac0.0-277.00.1± (1.5% of reading + 2counts), 60.0~277VCurrent, Aac0.0-30.00.1± (2% of reading + 2counts)Power, Watts0-84001± (5% of reading + 6 counts)Power, Factor0.000-1.0000.001W/VA, calculated and displayed to three significant digitsLeakage Current, mA0.00-10.000.01± (2% of reading + 2 counts)MD CircuitLeakage Current measuring resistance = 2K Ω ±1%Timer, second0.0-999.90.1± (0.1% of reading + 0.05 sec)TOUCH CURRENT TEST DUTDUT Input Power Rating0 - 277.0V, Single phase unblance, 30A maximumCurrent30A maximun continuousDUT ProtectionShort Circuit current 50A < 3 sec, Inrush Current 180A Response time 10u sec.SETTINGS HI and LO Limit, mARange 0.00-10.00mA, Resolution 0.01mA,Hi-Limit 0=OFFDelay Time, secondRange 0, 1.0-999.9 (0=continous), Resolution 0.1second.Compliance StandardsA UL544 NPB IEC60990 Fig4 U2 X External MD(1K Ohm)F Frequency check, External MD(1K Ohm)Line ConditionNEUTRAL, REVERSE, GROUNDProbe settingsG-L, G-NCURRENT MEASUREMENT Frequency RangeDC-100KHzTouch current Range(RMS)ResolutionAccuracy (DC,15-100KHz)0.00mA - 10.00mA0.01±(2% of reading + 3counts)Touch current offsetResolutionAccuracy (DC,15-100KHz) 0.00mA - 2.00mA0.01±(2% of reading + 3counts) LINE VOLTAGE MEASUREMENTRange0.0-277.0 VACResolution0.1 VAccuracy± (1.5% of reading +0.2V), 60.0-277.0VExternal MDBasic measuring element 1K ΩMD A - D componentsAccuracy: Resistance ± 1% Capacitance ± 5%MD Voltage LimitMaximum 30V peak or 30VDCExternal Terminal onTC, allowing for High,Low, Open settings(Option)Add a extemal chanel to reach P-G, S-G and P-S for hipot test. Extemal chanelHV relayGND relayP-GOpenONONS-GHighOFFONP-SLowonOFFGENERALPLC Remote ControlInput : Test, Reset, Interlock, Recall Memory 1-61.Minimun 5ms Plus time for Remote Input key.2.It need 100ms for test key - output (ACW,DCW,IR,GB). RUN and LLT need 200ms.3.It need 100ms for reset key - output shutdown.4.It need 100ms for interlock - output shutdown.5.Minimun stable data time on Memory Select input need 300ms.6.Maximun 2ms between Memory bit changes.Output:- Pass, Fail, Test-in-Process1.Output relay contact ratings is 1A/125V2.The output is separation outputMemory 20 memories, 10 steps, step and step can link.RUN and LLT step by step need 1.S, other need 100ms. Single step modeRemote Outputprovide the +24V, GND and I/O1~7 to control 67xx and 68xx AC Power Source or Transformer Box 1931Display20 x 2 LCD LED displayBUS REM(WITH RS232), LOCK, NEUTRAL, REVERSE, GROUND InterfaceOptional RS232SecurityKey Lock capability to avoid unauthorized access to all test parameters. Memory Lock capability to avoid unauthorized access to memory locations.Fail stopThis allows the 6330 to be configured to continue testing after detecting a failure.All pass/fail results are displayed at the completion of the test cycle.Alarm Volume SettingRange : 0~9 ; 0=OFF, 1 is softest volume, 9 is loudest volume. CalibrationSoftware and adjustments are made through the front panel.Environment0-40 ℃ , 20-80%RH Dimensions/Net Weight430mm(W)×133mm(H)×500 mm(D)/22KgSTANDARD ACCESSORIESPower Cord(10A)x1Fuses×2 (Including a spare contained in the fuse holder)Interlock Disable Key(1505)x1Hipot Test Lead, 1.5m (1101)x1Ground Bond Test Lead 40A, 3m(1153)x1Ground Bond Return Lead 40A, 3m(1152)x1LLT Receptacle Adaptor Box 30A , 1.6m(1932)x1DUT Power Input Lead 40A, 3m(1151)x1DUT Power Output Lead 40A, 3m(1150)x1